Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
English (US)
US English (US)
DE German
  • Home

JYR 500 g- 20 kg with USB port - Roasting Intelligence (RI) Setup (Beta)

This manual covers a connection of the JYR 500 g- 20 kg with USB port roast machine to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at July 25th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements  Supported measurements Roasting Intelligence setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

This roast machine is currently in the Beta stage of development at Cropster.

To access this integration, please register for Beta testing by completing the provided form here.

Beta testing involves the evaluation of new features by a limited group of users to uncover potential minor issues that may not be apparent during internal testing. 

Your feedback is crucial in helping us improve the functionality of our product. Please let us know in case you come across any unexpected behavior.

We will be happy to assist in resolving any issues you may encounter or propose alternative connection options.

 

Specifications


Requirements 

 

  • USB cable
  • FTDI Serial driver 


Supported measurements

 

Bean temperature [°]

Environmental temperature [°]

Drum temperature [°]

Set temperature control [°]: Refers to the Drum temperature.

Fan speed [Hz]

Drum speed [Hz]: Only JYR 3kg and above.

Drum pressure [Pa]

JYR models 500g to 2kg do not provide Drum speed measurement.

Older discontinued JYR models provide an Inlet temperature measurement, which is not supported by the Roasting Intelligence (RI) integration.

Roasting Intelligence setup

Installing the Roasting Intelligence (RI) software

 

  1. Download the custom version of Roasting Intelligence (RI) depending on your computer's Operating System here. 

Complete the installation process by following the steps provided.

  1. Double-click the Cropster icon on your desktop to access Roasting Intelligence (RI).
  2. Click the green Login with the browser button.
    💡 Select the "Remember me on this device" option to save your login credentials for future access.
    Screenshot 2025-03-26 at 12.10.43
     
  3. You will be directed to the C-sar browser. 
    Screenshot 2025-03-26 at 11.46.59
  4. Enter your Username* and Password* and click the green Sign in with password button.
    💡You need to use the same credentials that you use to access the online platform C-sar.

Check out the Release notes for every version of RI5 to stay updated on the latest features and improvements. You can access the Release notes directly in RI by clicking on Help > Release Notes.

 

 

Establishing a connection to the machine
 

The images displayed below are meant to serve as reference examples; however, they may differ slightly from what you will see on your screen.

 


Before you begin configuring your roast machine, ensure that you have added it via the online platform, C-sar.

Click gear-png Preferences > Machine > Configuration at the bottom left to access the Preferences screen. 

To choose the Roast machine, click on the dropdown menu in the Machine section.

By clicking on the + Add connector option, you can choose your connector from the available options in the dropdown list.

You need to select JYR PIDs from the dropdown. 

Click Select to add the connector.
Screenshot 2025-05-28 at 09.21.07

Navigate to the Machine > Measurements tab. All supported measurements will be displayed.

To activate the measurements, simply click the green toggle button.

Switch on the measurements you would like to enable and select JYR PIDs from the dropdown. 
💡 Make your measurement readouts more compact. Choose the size of your measurement readouts by selecting either the Small or Large view for display.

Change the order of the measurements by using the Drag and Drop icon and move it into position.
Screenshot 2025-04-01 at 10.09.42

  1. Navigate back to the Machine > Configuration tab and click on the gear-png-1Gear icon in the Connector setup section next to the previously added connector to open and configure more settings.
    Screenshot 2025-05-28 at 09.28.53
  2. Select the following details: 
    •  
      • Serial port:
        • Windows: Choose the COMx option that refers to the connection of the roast machine.
        • Mac: Choose the USBx option that refers to the connection if the roast machine.
           

Temperature unit: Choose Celsius or Fahrenheit, according to the temperature unit displayed from the machine's temperature readouts.

  1. Click OK.
  2. Click Save to finalize the changes.

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

Screenshot 2025-05-28 at 09.30.50

📚 Learn more about the Roasting Intelligence (RI) Preferences. 

Troubleshooting


If the RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the roast machine connected to the computer? 
  • Have you downloaded the driver for the USB serial converter, according to the manufacturing year of the machine?
  • Is the correct serial port within the RI selected?

If you have selected a serial port from the RI, and you receive Sources connected from the bottom-right corner of the roasting application, but you can't see live temperature readouts, you may not have selected the serial port referring to the roast machine's connection.

 

Congratulations! You have successfully set up the Cropster Roasting Intelligence!

Check out the Roasting Intelligence (RI5) - Getting Started manual and enjoy tracking your first roasts! More manuals and videos can be found on help.cropster.com. 

smart roaster advanced control

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Toper (with USB port) - Roasting Intelligence (RI) Setup (Beta)
  • Trinitas T2/T7 roast machine (via USB) - Roasting Intelligence (RI) Setup (Beta)
  • Trobrat (with Siemens S7 PLC)- Roasting Intelligence (RI) Setup

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand