Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
English (US)
US English (US)
DE German
  • Home
  • Connecting your roast machine
  • Plug&Play connectors

Yoshan/Dongyi - Roasting Intelligence (RI) Setup (Beta)

This manual covers the connection of a Yoshan/Dongyi roast machine to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at August 14th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Supported measurements Setting up a connection Via Bluetooth Via data cable Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

This roast machine is currently in the Beta stage of development at Cropster.

To access this integration, please register for Beta testing by completing the provided form here.

Beta testing involves the evaluation of new features by a limited group of users to uncover potential minor issues that may not be apparent during internal testing.

Your feedback is crucial in helping us improve the functionality of our product. Please let us know in case you come across any unexpected behaviour.

We will be happy to assist in resolving any issues you may encounter or propose alternative connection options.

 


Specifications

Requirements

  • USB cable
  • Driver for the USB serial converter:
    • Windows: CP210x Universal Windows Driver
    • macOS: Mac OSX VCP Driver

Supported measurements

  • Bean temperature
  • Exhaust temperature


Setting up a connection

Via Bluetooth

  1. Access your computer's Bluetooth interface.
    • On macOS: Navigate to the Apple icon > System preferences > Bluetooth.
    • On Windows: Go to Settings > Bluetooth & devices.
  2. Turn on Bluetooth, and connect to the device HC-0X (e.g., HC-06, HC-02).
  3. Input the match code 1234.
  4. Proceed with the Roasting Intelligence (RI) Setup.

 

Some computers may not be compatible with a Bluetooth connection, and alternatively, connect via a data cable.

 

 

Via data cable 

  1. Turn on the power to the roast machine.
  2. Plug the data cable into the roast machine's communication port.
  3. Connect the cable to the computer's USB port.
  4. Proceed with the Roasting Intelligence (RI) Setup.


Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access RI.
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser. 
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar. 
 

Establishing a connection to the machine

 

The images below are for reference and may vary slightly from your screen.

 


Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Generic Modbus over serial from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Controls tab.
  7. To activate the controls, simply click the green toggle button. Enable the controls you wish to activate.
  8. Choose Generic Modbus over serial as the connector type.
  9. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  10. Navigate back to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings based on the manufacturing year, as shown below.
  11. Choose Celsius or Fahrenheit according to the temperature unit displayed on the machine's temperature readouts.

Operation system 

Serial port 

Windows

COMx

Mac

USBx

Before May 2017


After May 2017

  1. Leave the empty fields as they are.
  2. Click OK.
  3. Click Save to finalize the changes.

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

Learn more about the Roasting Intelligence (RI) Preferences. 

 

 

Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the roast machine connected to the computer? 
  • Have you downloaded the driver for the USB serial converter?
  • Is the correct serial port within the RI selected?

Alternative configuration

If you are receiving Sources connected, and you have selected the Serial port referring to the connection of the roast machine, but you do not have any temperature measurements, try the following settings:

  1. Navigate to Preferences > Machine > Configuration. 
  2. Verify that the Roast machine you would like to connect from the dropdown menu (e.g., Yoshan YS-10) is still selected.
  3. By clicking on the + Add connector option, you can choose your connector from the available options in the dropdown list.
  4. You need to select Generic Modbus over serial from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Switch on the measurements you would like to enable and select Generic modbus over serial port from the dropdown. 
  9. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  10. Navigate back to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings based on the manufacturing year, as shown below
  11. Copy the settings as shown in the screenshot below, and select the Serial port and Temperature unit:
    • Serial port:
      Windows: Choose the COMx option that refers to the connection to the roaster.
      Mac: Choose the USBx option that refers to the connection to the roaster.
    • Temperature unit: Choose Celsius or Fahrenheit according to the temperature unit displayed from the machine's temperature readouts.
  12. Leave the empty fields as they are.
  13. Click OK.
  14. Click Save to finalize the changes. 

If you have selected a serial port from the RI, and you receive Sources connected from the bottom-right corner of the roasting application, but you can't see live temperature readouts, you may not have selected the serial port referring to the roast machine's connection.

 

 

The temperature decimal is in the incorrect location, or other connection issues

To solve these issues, you need to download the custom version of Roasting Intelligence (RI), depending on your computer's Operating System, here. 

If you are utilizing a custom version of Roasting Intelligence (RI), please take a moment to sign up via this form.

 

Congratulations! You have successfully set up the Cropster Roasting Intelligence.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

yoshan_dongyi roasting setup

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Roasting Intelligence (RI5) - Getting Started
  • Roasting Intelligence (RI5) Preferences
  • How to change the measurement size in RI5

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand