How to troubleshoot temperature deviation (Phidgets setup)

This article examines potential causes for temperature deviation between your roast machine and Cropster when connected via a Cropster Connector or Phidget.

Written by Nikolett Takacs

Updated at July 18th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Minor deviation (< 5°C/9F) Splicing Sensor setup Major deviation Physical connection Roasting Intelligence (RI) configuration Contacting Customer Support

To effectively troubleshoot a deviation, it is essential to differentiate between the two categories:

  1. A minor deviation that can occur naturally (depending on the setup).
  2. A major deviation that might indicate a setup error.

Minor deviation (< 5°C/9F)

A minor deviation, up to 5°C/9F, can be normal depending on the setup.

Potential causes for a minor deviation are a splicing connection or sensor setup. 

Splicing

A splicing connection can affect the potential being measured by the Phidget to calculate the actual temperature, which results in a small deviation.

If the deviation stays the same throughout the roast, an offset can be added to Cropster. 

Alternatively, we recommend focusing on the Cropster temperature readout only and ignoring the deviation. 

Sensor setup

When installing an independent probe connected to the Cropster, a deviation is very likely. Depending on where the newly added probe is placed, the temperature deviation can be bigger or smaller. The temperature can vary a lot inside the drum.

The best results can be achieved when installing an independent probe right next to the existing probe and making sure both probes have the same specifications (type, length, diameter). 

Also, with dual probes, a small deviation is possible. A dual probe carries two independent sensors within the probe hull, which measure the temperature independently from each other.

Generally, we recommend focusing on the Cropster temperature readout only, as Cropster is the tool you are developing the profiles with.

 

Major deviation 

A major deviation is a difference of more than 5°C or 9°F between the roast machine's readout and Cropster. 

The causes for a major deviation can vary. Deviation may be caused by, but not limited to:

  • Physical connection
  • Roasting Intelligence (RI) configuration

Physical connection

A deviation is often the result of a splicing connection set up incorrectly or wires connected to the wrong Connector port.

The thermocouple cable consists of a negative and a positive wire, which need to be spliced or connected to the Cropster connector accordingly. 

The negative wire needs to be connected to the "G" port and the positive wire to the respective number port (as shown in the example of a K-type thermocouple connected to a Cropster Connector below):

If a splicing connection is set up, negative wires and positive wires need to be connected to ensure an exact readout. Verify that the two leads from your probe wire have been spliced with the corresponding leads from the splicing wire according to polarity (+ to + / - to -).

Disconnect the USB cable from the Phidget/Cropster Connector and turn off your roast machine while you check the splicing connection.

 

Roasting Intelligence (RI) configuration

A deviation can occur if the type of Thermocouple has been entered incorrectly in the RI settings. Cropster supports thermocouples of types J, K, T, and E. 

Make sure the thermocouple type within the machine settings is assigned correctly by following these steps:

  1. Log in to the Roasting Intelligence (RI).
  2. Navigate to thePreferences on the bottom left side of the screen. 
  3. Select the Machine tab and Configuration.
  4. Scroll to the Type section, which is in the middle of the screen. 

Learn how to identify the probe type. 

 

Contacting Customer Support

Please create a support ticket via support.cropster.com and provide the following information:

  • A general description of the problem (how big is the deviation, is it static or dynamic, etc.)
  • Attach the RI log files (to be exported via Help > Export log files)
  • Pictures of the physical connection (of the Cropster Connector, the thermocouple wires, the splicing connection, etc.)

Congratulations! You have learned how to troubleshoot temperature deviation.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com.

troubleshoot deviation

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • How to resolve POS Data upload issues
  • Troubleshooting Roasting Intelligence (RI) syncing issues
  • Troubleshooting Roasting Intelligence (RI) connection issues ("No sources connected")

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand