Nordic Roaster with manual controls - Roasting Intelligence (RI) Setup
This manual covers the connection of the Nordic roaster with manual controls (1, 3, 7, 12kg) to Cropster's Roasting Intelligence.
Table of Contents
Specifications
Requirements
- Ethernet cable
Supported measurements
- Bean temperature
- Exhaust temperature
More measurements for Manual Nordic models with 15kg and 30kg volume, Manual Nordic MP models, and Auto control Nordic models are available on Beta.
To access this integration, please register for Beta testing by completing the provided form here.
Setting up a connection
Via the computer
.webp)
- Connect the network cable to your roaster's Ethernet port
- Connect the other end to the computer's Ethernet port.
- Proceed with the Network settings.
Network settings
When the roaster is connected to the computer directly, you need to set up a Static IP address.
Static IP address configuration - Windows 7, 8, 10
- Navigate to the Control Panel > Network and Sharing Center or Network and Internet > Network Sharing Center.
- Click Change adapter settings.
-
Identify the Network connection item that refers to the connection to your machine and select that item.
If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status. - Right-click on WiFi or Local Area Connection.
- Click Properties.
- Select Internet Protocol Version 4 (TCP/IPv4).
- Click Properties.
- Select the Use the following IP Address option.
-
Enter the specific IP Address for your roaster and replace the fourth number block with 42:
-
IP Address: 192.168.97.42
Important: The first three blocks of the IP address need to match the IP address of your roaster, as identified via the roaster's panel. - Subnet mask: 255.255.255.0
-
IP Address: 192.168.97.42
- Leave the rest blank.
- Click the OK button to submit your changes.
Static IP address configuration - macOS
- Navigate to
> System Preferences > Network
-
Identify the Network connection item that refers to the connection to your machine and select that item.
If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status. - Click on Details…
- Open the TCP/IP section and choose Manually next to Configure IPv4.
-
Enter the specific IP Address for your roaster and replace the fourth number block with 42:
- IP Address: 192.168.97.42
- Subnet mask: 255.255.255.0
- Click the OK button to confirm the changes.
- Proceed with the Roasting Intelligence (RI) Setup
Roasting Intelligence (RI) Setup
Installing the Roasting Intelligence (RI) software
- Download RI.
- Complete the installation process by following the steps provided.
- Double-click the Cropster icon on your desktop to access RI.
-
Click the green Login with the browser button.
-
You will be directed to the C-sar browser.
-
Enter your Username* and Password* and click the green Sign in with password button.
Use the same credentials that you use to access the online platform C-sar.
Establishing a connection to the machine
The images below are for reference and may vary slightly from your screen.
Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.
- Select
Preferences > Machine > Configuration
- To choose the Roast machine, click on the dropdown menu in the Machine section.
- Click the + Add connector option to choose your connector from the dropdown list.
- Select Nordic Coffee PIDs from the dropdown.
-
Click Select to add the connector.
- Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
- To activate the measurements, simply click the green toggle button.
- Enable the desired measurements and choose Nordic Coffee PIDs as the connector type.
-
(Optional) Change the order of the measurements by using the
Drag and Drop icon and move it into position.
- Navigate to the Machine > Configuration tab and click on the
Gear icon in the Connector setup section to open and configure more settings.
-
Enter the IP address of the roast machine.
The default for Nordic roasters is 192.168.97.7 - Click OK.
- Click Save to finalize the changes.
After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.
.webp)
Learn more about the Roasting Intelligence (RI) Preferences.
Troubleshooting
If RI indicates No source connected and/or you cannot see any measurements, please check the following:
- Is the static IP address configured correctly?
- Does the IP address of your roaster differ from the default?
Congratulations! You have successfully set up the Cropster Roasting Intelligence.
Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com.