This manual covers the connection of a Probat P01 (PIII series) to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at August 5th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Supported measurements Switch controls Via the network router Via the computer  Network settings Static IP address configuration - Windows 7, 8, 10 Static IP address configuration - macOS Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

Specifications

Requirements

  • Ethernet cable

Supported measurements

  • Bean temperature
  • Exhaust temperature
  • Inlet temperature
  • Drum pressure (pa)
  • Drum speed
  • Drum speed control
  • Gas (%)
  • Gas control

Switch controls

  • Cooler
  • Stirrer
  • Standby
     

Setting up a connection

For Probat P01, a connection via the network router is recommended. 

 


Via the network router

  1. Connect your roaster with an Ethernet cable to your network router.
    The DHCP server assigns an IP address to your roaster. The IP address appears in the top bar on the roaster's display. 
    The IP address and DNS name of your Probat differ from the screenshot.
  2. Make sure that your computer is connected to the local network.
  3. Proceed with the Roasting Intelligence (RI) Setup.


Via the computer 

To access the web interface and configure a static IP address, Probat P01 requires a connection via the network router for the first connection.

 

 

  1. Connect your roaster with an Ethernet cable to your network router, as described under this manual's Via the network router-section.
  2. Check the IP address on your roaster's display. 
  3. Open your browser and enter the IP address that appears on the Probat display in the address bar of your browser to access the IP settings. 
  4. Go to Settings > General and change the Configuration from DHCP to Manual. 
  5. Restart the roaster. 
  6. Disconnect the roaster from the network router and connect it to your PC. 
  7. The IP address should be shown on the display. 
  8. Proceed with the Network settings.


Network settings

When the roaster is connected to the computer directly, you need to set up a Static IP address. 

 

 

Static IP address configuration - Windows 7, 8, 10

  1. Navigate to the Control Panel > Network and Sharing Center or Network and Internet > Network Sharing Center.
  2. Click Change adapter settings. 
  3. Identify the Network connection item that refers to the connection to your machine and select that item.
    If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status.
  4. Right-click on WiFi or Local Area Connection. 
  5. Click Properties. 
  6. Select Internet Protocol Version 4 (TCP/IPv4). 
  7. Click Properties.
  8. Select the Use the following IP Address option.
  9. Enter the specific IP Address for your roaster and replace the fourth number block with 42:
    In this example, the IP address of the machine is 10.20.0.211.
    • IP Address: 10.20.0.42* 
      Important: The first three blocks of the IP address need to match the IP address of your roaster, as identified via the roaster's panel.
    • Subnet mask: 255.255.255.0
    • Leave the rest blank.
  10. Click the OK button to submit your changes.
  11. Proceed with the Roasting Intelligence (RI) Setup.
 
 

 

Static IP address configuration - macOS 

  1. Navigate to > System Settings > Network.
  2. Identify the Network connection item that refers to the connection to your machine and select that item.
    If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status.
  3. Click on Details...
  4. Open the TCP/IP section and choose Manually next to Configure IPv4.
  5. Enter the specific IP Address for your roaster and replace the fourth number block with 42:
    In this example, the IP address of the machine is 10.20.0.211.
    • IP Address: 10.20.0.42* 
      Important: The first three blocks of the IP address need to match the IP address of your roaster, as identified via the roaster's panel.
    • Subnet mask: 255.255.255.0
  6. Click the OK button to confirm the changes.
  7. Proceed with the Roasting Intelligence (RI) Setup.
 
 

 

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access RI.
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser. 
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.
 

Establishing a connection to the machine

The images below are for reference and may vary slightly from your screen.

 

Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Probat Websocket (PIII Series) from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose Probat Websocket (PIII Series) as the connector type.
  9. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  10. Navigate to the Machine > Controls tab. 
  11. To activate the controls, simply click the toggle button. Enable the controls you wish to activate.
  12. Choose Probat Websocket (PIII Series) as the connector type.
  13. Navigate to the Machine > Switch controls tab. To activate the Switch controls, simply click the toggle button. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position
  14. Navigate to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings.
  15. Navigate to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings.
  16. Check the IP address from your roaster's display.
    If the IP address is shown as 0.0.0.0, you are not connected properly. Please check your connection. 
  17. Enter the IP address from the Probat display. 
  18. Click OK. 
  19. Click Save to finalize the changes.

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

Learn more about the Roasting Intelligence (RI) Preferences. 

 


Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the IP address correct?

When using Replay Assist:

Do not use the Probat Pilot roaster shop or any other temperature-controlling software in parallel.
Any gas/airflow changes from a concurrent client disable Replay assist for the remainder of the roast. 

 

 


Congratulations! You have successfully set up the Cropster Roasting Intelligence.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

 

probat ri setup probat p01 piii series

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • How to customize the Brew logging parameters
  • Multi-barrel setup doesn't display temperatures
  • Viewing the Between Batch Protocol (BBP) data during post-roast analysis

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand