Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
English (US)
US English (US)
DE German
  • Home
  • Connecting your roast machine

Coffee-Tech Silon, Ghibli Models (via USB) Roasting Intelligence Setup (Beta)

This manual covers the connection of Coffee-Tech Silon and Ghibli Models to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at February 2nd, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roast
    Getting Started Inventory Management Sample Management Roast Scheduling Roasting Processes Reporting Troubleshooting
  • Roasting Intelligence
    Getting Started Using Roasting Intelligence Roasting Intelligence AI Features Customization and Preferences Troubleshooting
  • Cafe
    Espresso machine connection Getting Started Cafe Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Origin
    Getting Started Operations Reporting
  • Quality Control
    Cupping Physical Analysis
  • Sharing & Exporting Cropster Data
  • Account & Administration
    General Account Management General User Management Troubleshooting
+ More

Table of Contents

Specifications Requirements Supported measurements Roasting Intelligence Setup Installing the Roasting Intelligence software Establishing a connection to the machine Troubleshooting

This roast machine is currently in the Beta stage of development at Cropster.
To access this integration, please register for Beta testing by completing the provided form here.

 

Specifications

Requirements

  • USB cable
  • Driver for the USB serial converter

 

The driver may already be pre-installed with your operating system.

 

 

Supported measurements

  • Bean temperature
  • Exhaust temperature
  • Drum temperature
  • Airflow [%]
  • Drum speed [MHz]


Roasting Intelligence Setup

Installing the Roasting Intelligence software

  1. Download the custom version of Roasting Intelligence depending on your computer's Operating System.
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access Roasting Intelligence.
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser.
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.


Establishing a connection to the machine

 

The images below are for reference and may vary slightly from your screen.

 

 

Important details to keep in mind:

  • Before you start configuring your roast machine, ensure that you have added it via the online platform C-sar.
  • Only click Save after you've completed all settings in Roasting Intelligence.
 

 

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Coffee-Tech Beta (PIDs over serial/USB) from the dropdown. 
  5. Click Select to add the connector.
  6. Click on the Gear icon in the Connector setup section to open and configure more settings.
  7. Select the Serial port and the Model:
    • Serial port: tty.usbserial-x (maOsc) or COMx (Windows)
    • Model: Silon or Ghibli.
    • Baud rate and Stop bits: These values might differ from machine to machine. 
      Please try the different combinations:
      Blaud rate: 19200
      Stop bits: 2. 
  8. Click OK.

 

  1. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  2. To activate the measurements, click the green toggle button.
  3. Enable the desired measurements and choose Coffee-Tech Beta (PIDs over serial/USB)  as the connector type.
  4. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position
  5. Click Save to finalize the changes.
  6. Restart Roasting Intelligence. If the setup was successful, you will see the temperature values displayed on the right-hand side of the screen following the restart.

     

Learn more about the Roasting Intelligence Preferences. 

 


Troubleshooting

The machine is successfully connected, but Roasting Intelligence indicates 0 for the Drum speed and Airflow:

  • Make sure the drum is turned on.

If Roasting Intelligence indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the roast machine connected to the computer? 
  • Have you downloaded the driver for the USB serial converter?
  • Is the correct serial port within Roasting Intelligence selected?
     

⚠️  If Roasting Intelligence shows "Sources connected" but no temperatures appear, you likely selected the wrong serial port. Check your settings and select the port corresponding to your roast machine.

 


Driver for the USB serial converter

If you cannot select the correct serial port within the Serial port field, your computer may not have the appropriate driver needed to recognize the serial converter's physical connection.

Please reach out to support.cropster.com, and attach the following information relevant to the USB serial converter used:

  1. Brand and model
  2. Serial number
  3. Picture of the serial converter
  4. Roasting Intelligence log files 

If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

 

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Coffee-Tech FZ-94 (via USB) Roasting Intelligence Setup
  • Coffed Manual SR3, SR5 and SR5 Delta Models (with USB port) - Roasting Intelligence Setup
  • Primo with Delta DTB controller (with USB port) (Beta)

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand