J/K/T/E type thermocouples (splicing connection) - Roasting Intelligence (RI) Setup

This manual explains how to connect your roast machine to the Cropster Connector by establishing a splicing connection to your J/K/T/E type thermocouples.

Written by Nikolett Takacs

Updated at July 30th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Hardware installation Splicing wire installation Cropster Connector installation Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

 

Legal Note

Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.

By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence (RI) software, the user agrees to release Cropster from any liability and assumes any possible risk related to using this measuring device and/or software. Cropster's terms of service apply.

Cropster cannot advise on the installation of the hardware. To ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation. 

 


Specifications

Requirements

  • Ungrounded digital thermocouples type K, J, T, or E
  • Cropster Connector (Phidget 1048)
  • Splicing wire (ad-hoc)


Hardware installation

Disconnect the USB cable from the Cropster Connector and turn off your roast machine during the hardware installation.

Splicing wire installation

The following instructions only apply to models where one can unwire and wire the thermocouples without breaking connectors or other machine parts.

  1. Follow the probe cable from the tip of the probe to its end where the two wires lead into the roaster's control board or the backside of the temperature display.
  2. Take out the temperature probe wires from where they are connected. Remember their position.
    Take a picture before you disconnect the wires, so you can look up their position.
    EURO standard K-type probes (in this example, wires go into a control board. Instead of a roast control board, you may have a temperature display on your machine. Temperature probe wires (and splicing wires) look different depending on the standard your machine uses.
  3. Take the splicing wire as provided with your Cropster Connector.
  4. Twirl the ends of the probe wires firmly together with the splicing wires by polarity. Connect the positive splicing wires to the corresponding positive probe wires, and similarly, attach the negative splicing wires to the negative probe wires.
    This example shows EURO standard K-type probes and wires.
  5. Put the twirled wires back into the original position (the existing readout) of the temperature probe wires.


Cropster Connector installation

  1. Find the free end of the splicing wire. 
  2. Connect the two wires to any port of the Cropster Connector (e.g., 0/G, 1/G, 2/G, 3/G) with the provided screwdriver, as shown in the table below.
  3. Connect the Cropster Connector via the provided USB cable and proceed with the Roasting Intelligence Setup.

EURO-standard

US-standard

K-type

  • Green wire to number port (e.g. 0)
  • White wire to corresponding G port

K-type

  • Yellow wire to number port (e.g., 0)
  • Red wire to corresponding G port

J-type

  • Black wire to number port (e.g. 0)
  • White wire to corresponding G port

J-type
 

  • White wire to number port (e.g., 0)
  • Red wire to corresponding G port

Eventually, the connection will look similar to the graph below.

 

Do not attach or place the Cropster Connector in or onto any hot environment.

 

 

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.
  3. Download the Phidget driver.
  4. Click the green Login with the browser button
  5. You will be directed to the C-sar browser. 
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.
 

Establishing a connection to the machine

The images below are for reference and may vary slightly from your screen.

 

Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar. 

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Temperature sensor (Ungrounded K/J/E/T-type thermocouples) from the dropdown. 
  5. Click Select to add the connector. 
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose Temperature sensor (Ungrounded K/J/E/T-type thermocouples) as the connector type.
  9. Select the Channel.
    The channel refers to the ports on the Cropster Connector. If the probe wires are connected to port 1/G, select 1 under the channel. 
  10. Select the Type of thermocouple.
  11. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  12. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  13. Click Save to finalize the changes. 

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.


Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the Cropster Connector connected to the computer? 
  • Is the Phidgets driver installed?
  • Mac only: has the Phidgets driver been enabled in the Mac's Security & Privacy settings?

If Roasting Intelligence shows negative temperature readings, you will have to swap the wires on the board from “G” to “0” (or 1, 2, 3) and the other way round.

 

Congratulations! You have successfully set up the Cropster Roasting Intelligence

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

thermocouple types roasting setup

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • HUB5000 - Roasting Intelligence (RI) Setup (Beta)
  • Adding control measurements to Roasting Intelligence (RI)

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand