Diedrich (without sensor package) - Roasting Intelligence (RI) Setup
This manual covers hardware connection, software installation and settings of Cropster’s Roasting Intelligence on Diedrich machines without pre-installed sensor package.
Table of Contents
Legal Note
Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.
By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence (RI) software, the user agrees to release Cropster from any liability and assumes any possible risk related to the use of this measuring device and/or software. Cropster's terms of service apply.
Cropster cannot advise on the installation of the hardware, and to ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation.
Specifications
Requirements
-
Usually, Diedrich machines come with K-type Thermocouples
Learn how to identify your Thermocouple type. - Cropster Connector (=Phidget 1048)
-
Splicing wire (K-type)
Setup options
Dual probe connection (Recommended)
Replace your current sensors with dual probes.
A dual probe is a probe with two sensors inside the hull and two pairs of wires that allow a simultaneous connection to Cropster and the roaster's readout.
Proceed with the Cropster Connector installation.
Splicing connection
Cropster explicitly does not recommend hardware connection via splicing.
Your Cropster support person will gladly recommend different connection options for your machine.
Learn more about how to establish a splicing connection.
Cropster Connector installation
Disconnect the USB cable from the Cropster Connector and turn off your roast machine during the hardware installation.
-
Follow the probe cable from the tip of the probe to its end, where the two wires appear.
In the case of dual probes, take the free end that is not connected to the roaster. - Connect the two wires to any port of the Cropster Connector (e.g., 0/G, 1/G, 2/G, 3/G) with the provided screwdriver, as shown in the table below.
- Connect the Cropster Connector via the provided USB cable and proceed with the Roasting Intelligence Setup.
EURO-standard |
US-standard |
K-type
![]() |
K-type
![]() |
J-type
![]() |
J -type
![]() |
Roasting Intelligence (RI) Setup
Installing the Roasting Intelligence (RI) software
- Download RI.
- Complete the installation process by following the steps provided.
- Download the Phidget driver.
- Double-click the Cropster icon on your desktop to access Roasting Intelligence (RI).
-
Click the green Login with the browser button.
-
You will be directed to the C-sar browser.
-
Enter your Username* and Password* and click the green Sign in with password button.
Use the same credentials that you use to access the online platform C-sar.
Establishing a connection to the machine
The images below are for reference and may vary slightly from your screen.
Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.
- Select
Preferences > Machine > Configuration
- To choose the Roast machine, click on the dropdown menu in the Machine section.
- Click the + Add connector option to choose your connector from the dropdown list.
- Select Temperature sensor (Ungrounded K/J/E/T-type thermocouples) from the dropdown.
-
Click Select to add the connector.
- Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
- To activate the measurements, simply click the green toggle button.
- Enable the desired measurements and choose Temperature sensor (Ungrounded K/J/E/T-type thermocouples) as the connector type.
-
Select the Channel and Type.
The channel refers to the ports on the Cropster Connector. If the probe wires are connected to port 1/G, select 1 under the channel. -
(Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
- (Optional) Change the order of the measurements by using the
Drag and Drop icon and move it into position.
-
Click Save to finalize the changes.
After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.
.webp)
Learn more about the Roasting Intelligence (RI) Preferences.
Troubleshooting
If RI indicates No source connected and/or you cannot see any measurements, please check the following:
- Is the Cropster Connector connected to the computer?
- Is the Phidgets driver installed?
- macOS only: has the Phidgets driver been enabled in the Mac's Security & Privacy settings?
If Roasting Intelligence shows negative temperature readings, you will have to swap the wires on the board from “G” to “0” (or 1, 2, 3) and the other way round.
Congratulations! You have successfully set up the Cropster Roasting Intelligence.