Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
English (US)
US English (US)
DE German
  • Home
  • Connecting your roast machine
  • Plug&Play connectors

Joper BR VERSION II ADVANCED/PREMIUM - Roasting Intelligence (RI) Setup (Beta)

This manual covers the connection to Joper BR VERSION II ADVANCED/PREMIUM roast machines to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at August 5th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Supported measurements Setting up a connection Via the computer Network settings Static IP address configuration - Windows 7, 8, 10, 11 Static IP address configuration - macOS Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

 

This roast machine is currently in the Beta stage of development at Cropster.

To access this integration, please register for Beta testing by completing the provided form here.

Beta testing involves the evaluation of new features by a limited group of users to uncover potential minor issues that may not be apparent during internal testing.

Your feedback is crucial in helping us improve the functionality of our product. Please let us know in case you come across any unexpected behavior.

We will be happy to help you resolve any issues you may encounter or propose alternative connection options.

 


Specifications

Requirements

  • Ethernet cable

Supported measurements

  • Bean temperature (°C)
  • Exhaust temperature (°C)
  • Environmental temperature (°C) (optional)
  • Other temperature (°C) (=Cooling temperature) (optional)
  • Gas (%)
  • Gas control
  • Drum pressure (Pa)
  • Airflow (%)
  • Airflow control
  • Drum speed (RPM)
  • Drum speed control

 

Please note:

  • The roaster can be controlled from the roaster's console and by Cropster RI at the same time.
  • Any control changes made in Cropster RI will disable the automatic mode of the roaster.
  • When using Cropster Replay Assist, please do not use the Brigus Software or any other temperature controlling software in parallel, as this could cause interference, and any control changes will disable Replay Assist for the remainder of the roast.
 

 

Setting up a connection

Via the computer 

  1. Connect the network cable to your roaster's Ethernet port 
  2. Connect the other end to the computer's Ethernet port.
  3. Proceed with the Network settings.


Network settings

When the roaster is connected to the computer directly, you need to set up a static IP address. 

 

 

Static IP address configuration - Windows 7, 8, 10, 11

  1. Navigate to the Control Panel > Network and Sharing Center or Network and Internet > Network Sharing Center.
  2. Click Change adapter settings. 
  3. Identify the Network connection item that refers to the connection to your machine and select that item.
    If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status.
  4. Right-click on WiFi or Local Area Connection. 
  5. Click Properties. 
  6. Select Internet Protocol Version 4 (TCP/IPv4). 
  7. Click Properties.
  8. Select the Use the following IP Address option.
  9. Enter the specific IP Address for your roaster and replace the fourth number block with 42:
    • IP Address: 192.168.100.42
    • Subnet mask: 255.255.255.0
    • Leave the rest blank.
  10. Click the OK button to submit your changes.
  11. Proceed with the Roasting Intelligence (RI) Setup.
 
 

 

Static IP address configuration - macOS 

  1. Navigate to> System Settings > Network.
  2. Identify the Network connection item that refers to the connection to your machine and select that item.
    If you are not sure which icon refers to the roast machine, simply disconnect and reconnect the Ethernet cable, and check which icon changes its status.
  3. Click on Details...
  4. Open the TCP/IP section and choose Manually next to Configure IPv4.
  5. Enter the specific IP Address for your roaster and replace the fourth number block by 42:
    • IP Address: 192.168.100.42
    • Subnet mask: 255.255.255.0
  6. Click the OK button to confirm the changes.
  7. Proceed with the Roasting Intelligence (RI) Setup.
 
 

 

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download the custom version of Roasting Intelligence (RI) depending on your computer's Operating System here. 
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access RI.
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser. 
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.
 

Establishing a connection to the machine
 

The images below are for reference and may vary slightly from your screen.

 


Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Joper PLC from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose Joper PLC as the connector type.
  9. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  10. Navigate to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings.
  11. Enter the IP address.
    The default Hostname/IP address: 192.168.100.20
  12. Click OK.
  13. Click Save to finalize the changes.

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

 

Learn more about the Roasting Intelligence (RI) Preferences and the Replay Assist. 

 


Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the IP address set properly in the Machine settings?
  • Have you established a static IP address? 

Congratulations! You have successfully set up the Cropster Roasting Intelligence.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

joper_br_version roasting intelligence

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Troubleshooting Roasting Intelligence (RI) syncing issues
  • Troubleshooting Roasting Intelligence (RI) connection issues ("No sources connected")
  • How can I calibrate my probes
  • Garanti with Delta controls (via USB) - Roasting Intelligence (RI) Setup

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand