Yocto-Thermocouple (J/K/E/T/N Type Thermocouples) - Roasting Intelligence Setup

This manual covers the hardware connection, software installation and settings of Cropster’s Roasting Intelligence for J/K/E/T/N type (UNGROUNDED) thermocouples, connected via a Yocto-Thermocouple device.

Written by Nikolett Takacs

Updated at February 2nd, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roast
    Getting Started Inventory Management Sample Management Roast Scheduling Roasting Processes Reporting Troubleshooting
  • Roasting Intelligence
    Getting Started Using Roasting Intelligence Roasting Intelligence AI Features Customization and Preferences Troubleshooting
  • Cafe
    Espresso machine connection Getting Started Cafe Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Origin
    Getting Started Operations Reporting
  • Quality Control
    Cupping Physical Analysis
  • Sharing & Exporting Cropster Data
  • Account & Administration
    General Account Management General User Management Troubleshooting
+ More

Table of Contents

Yocto-Thermocouple contents Specifications Requirements Connection options Direct connection Dual connection Yocto-Thermocouple Device Installation Roasting Intelligence Setup Installing the Roasting Intelligence software Establishing a connection to the machine Troubleshooting Erratic temperature curves (electrical interference)

 

Legal Note

We recommend reviewing the Yocto-Thermocouple's User's Guide before proceeding with the steps provided in this article.

Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.

By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence software, the user agrees to release Cropster from any liability and assumes any possible risk related to the use of this measuring device and/or software. Cropster's terms of service apply.

Cropster cannot advise on the installation of the hardware, and to ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation. 

 


Yocto-Thermocouple contents

  • Yocto-Thermocouple device
  • 2 Type-K 50cm fine-wire twisted-pair thermocouple cables

The USB 2.0 Type-A to Micro-B data cable, shown in the picture above, is sold separately from the Yocto-Thermocouple device. We recommend ungrounded thermocouples type K, J, T, E, or N.

 


Specifications
 

VirtualHub must be installed and active to enable Yoctopuce integration.

 

 

Requirements

  • Ungrounded, digital, thermocouples type K, J, T, E, or N
  • Yocto-Thermocouple device
  • USB 2.0 Type-A to Micro-B data cable

 

According to Yoctopuce, use a USB 2.0 Type-A to Micro-B data cable to connect the Yocto-Thermocouple to your computer. Do not buy a simple USB charging cable without data connectivity. The supported cable type is available from the Yoctopuce shop.

 

 

Connection options

Depending on the type of your roaster and thermocouples, there are two connection options: 

  1. Direct connection
  2. Dual probe connection


Direct connection

A direct connection applies when adding new probes independently of the roaster's readout. The newly added probe can be connected directly to the Yocto-Thermocouple device.


Dual connection

A dual connection applies when the roaster is equipped with a dual probe. A dual probe is a probe with two sensors inside the hull and two pairs of wires that allow a simultaneous connection to the Yocto-Thermocouple and the roast machine's readout.
If your machine uses single probes, you can upgrade to dual probes to enable a dual connection.


Yocto-Thermocouple Device Installation

 

For a safe and stable setup, please follow these requirements:

  • Disconnect the USB cable from the Yocto-Thermocouple and power off your roasting machine before starting the installation.
  • Avoid connecting USB devices through multiple "cascaded" (daisy-chained) hubs unless they have an external power supply.
  • If you must interconnect hubs, use self-powered USB hubs capable of providing a full 500mA to every port.
  •  Learn more about USB power distribution from Yoctopuce's User's Guide.
 

 

  1. Trace the probe cable to its wire-end. For dual probes, use the free end not connected to the machine.
  2. Connect the two wires from the probe, by polarity, to any channel of the Yocto-Thermocouple device with a screwdriver, as shown in the table below. Refer to the Yocto-Thermocouple's ports for the +/- symbols.
  3. Connect the Yocto-Thermocouple device to the computer with a USB-A cable.
  4. To enable Roasting Intelligence to connect to the Yocto-Thermocouple device, download and run the VirtualHub application provided by Yoctopuce here, and then proceed with the Roasting Intelligence setup. 

 EURO-standard

US-standard

 K-type

  • Green wire to the positive (+) port.
  • White wire to the corresponding negative (-) port.

K-type

  • Yellow wire to the positive (+) port.
  • Red wire to the corresponding negative (-) port.

 J-type

  • Black wire to the positive (+) port.
  • White wire to the corresponding negative (-) port.

J-type

  • White wire to positive (+) port.
  • Red wire to the corresponding negative (-) port.


Roasting Intelligence Setup

Installing the Roasting Intelligence software

  1. Download Roasting Intelligence. 
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access Roasting Intelligence. 
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser.
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar. 
 

Establishing a connection to the machine
 

The images below are for reference and may vary slightly from your screen.

 

 

Important details to keep in mind:

  • Before you start configuring your roast machine, ensure that you have added it via the online platform C-sar.
  • Only click Save after you've completed all settings in Roasting Intelligence.
 

 

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Yocto-Thermocouple from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, click the green toggle button.
  8. Enable the desired measurements and choose Yocto-Thermocouple as the connector type.
  9. Select the Channel. The channel refers to the ports on the Yocto-Thermocouple device.
  10. Select the Type of thermocouple.
  11. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  12. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  13. Click Save to finalize the changes.
  14. Restart Roasting Intelligence. If the setup was successful, you will see the temperature values displayed on the right-hand side of the screen following the restart. 

     

Learn more about the Roasting Intelligence Preferences. 

 


Troubleshooting

If Roasting Intelligence indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the Yocto-Thermocouple device connected to the computer?
  • Are the thermocouples connected to the Yocto-Thermocouple device?
  • If your Yocto-Thermocouple is connected by USB, and its blue LED is on, but if the operating system cannot see the module, check that you are using a true USB cable with data wires, and not a charging cable. Find the appropriate cable from the Yoctopuce shop.
  • If Roasting Intelligence displays negative temperatures, swap the wires between the positive (+) and negative (-) ports on the board.

 

Erratic temperature curves (electrical interference)

An erratic, or noisy, temperature curve is a common issue in PC-based, temperature-logging systems, and can originate from different sources:

  • Sensor noise
  • Signal wire noise
  • Ground loops

 

⚠️ The Yocto-Thermocouple lacks electrical isolation between its measuring and USB components. As Yoctopuce explains, this carries specific risks.

 

 


If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

temperature sensors coffee roasting yocto thermocouple

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • J/K/T/E type thermocouples (splicing connection) - Roasting Intelligence (RI) Setup
  • Sources of Noise
  • How to troubleshoot electrical interference (noise)

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand