Kapok with Delta DTA 4848 controls (via USB) - Roasting Intelligence (RI) Setup

This manual covers the connection of a Kapok roast machine via USB, to Cropster's Roasting Intelligence




Specifications

Requirements

Supported measurements

  • Bean temperature
  • Exhaust temperature
  • Inlet temperature: Only relevant to certain models.

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.

  3. Double-click the Cropster icon on your desktop to access RI.
  4. Enter your username and password.
    Use the same login information that you use to access the online platform C-sar.

  5. Click the Login button.

Check out the Release notes for every version of RI5 to stay updated on the latest features and improvements.

You can access the Release notes directly in RI by clicking on Help > Release Notes.


 Establishing a connection to the machine

  1. If you are setting up RI for the first time, click the Select machine button in the banner at the top or click Preferences > Machine > Configuration bottom left to access the Preferences screen. 
    📚 Learn how to use the keyboard shortcuts in RI.
  2. To choose the Roast machine, click on the dropdown menu in the Machine section

    💡 After selecting the machine from the dropdown menu, the roast machine settings may automatically be filled in. You have the flexibility to edit these settings at any time to ensure they align with the specifications of your roasting machine. 

    📚 Learn how to add a new roast machine. 
  3. After selecting the machine all supported measurements will load.
    Change the order of the measurements by using the  Drag and Drop icon and moving it into position.
  4. Switch on the measurements you would like to enable and select Kapok PIDs from the dropdown. 
    💡 Make your measurement readouts more compact. Choose the size of your measurement readouts by selecting either the Small or Large view for display.
  5. Click on the  Gear icon to open the PID settings.
  6. Select the Serial port that refers to the connection to the machine.
    💡 You need to choose the correct Slave ID (1, 2 or 3) for each temperature controller display. The correct Slave ID depends on the machine. The Slave ID for the inlet temperature can be left empty.
  7. Click OK.
  8. Click Save to finalize the changes.

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

    Screenshot 2024-08-13 at 13.54.12-1

    📚 Learn more about the Roasting Intelligence (RI) Preferences

    Troubleshooting

    If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

    • Is the roast machine connected to the computer? 
    • Have you downloaded the driver for the USB serial converter?
    • Is the correct serial port within the RI selected?

    If RI says Source connected but measurements are not shown or measurements are switched around, please try the following: 

    • Open the machine preferences and click the Gear icon next to any measurement to open the connector settings. 
      • Example 1 : If Bean temperature is showing the Exhaust value and vice versa, switch the values for Slave Id bean temp and Slave Id exhaust temp. 
      • Example 2 : If you don't get a value for a measurement, experiment with different Slave Id's for the measurements. 
        Slave Id bean temp: 1
        Slave Id exhaust temp: 2
        Slave Id inlet temp: Leave it empty. 

    Congratulations! You have successfully set up the Cropster Roasting Intelligence!

    Check out the Roasting Intelligence (RI5) - Getting Started manual and enjoy tracking your first roasts! More manuals and videos can be found on help.cropster.com