Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
English (US)
US English (US)
DE German
  • Home
  • Connecting your roast machine
  • Alternative connection options

VINT Hub + TMP1101 (J/K/E/T Type Thermocouples) - Roasting Intelligence Setup

Written by Nikolett Takacs

Updated at February 10th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roast
    Getting Started Inventory Management Sample Management Roast Scheduling Roasting Processes Reporting Troubleshooting
  • Roasting Intelligence
    Getting Started Using Roasting Intelligence Roasting Intelligence AI Features Customization and Preferences Troubleshooting
  • Cafe
    Espresso machine connection Getting Started Cafe Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Origin
    Getting Started Operations Reporting
  • Quality Control
    Cupping Physical Analysis
  • Sharing & Exporting Cropster Data
  • Account & Administration
    General Account Management General User Management Troubleshooting
+ More

Table of Contents

Specifications Requirements Setup options Direct connection Dual connection Splicing connection VINT Hub + TMP1101 installation Roasting Intelligence Setup Installing the Roasting Intelligence software Establishing a connection to the machine Troubleshooting
 

 

Legal Note

Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.

By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence (RI) software, the user agrees to release Cropster from any liability and assumes any possible risk related to the use of this measuring device and/or software. Cropster's terms of service apply.

Cropster cannot advise on the installation of the hardware, and to ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation. 

 


Specifications
 

Learn how to identify the Thermocouple type. 

 

 

Requirements
 

  • Digital thermocouples type K, J, T, or E
  • VINT Hub (HUB0001_0)
    • HUB0001_0 replaced the HUB0000_0
  • 4x Thermocouple Phidget (TMP 1101_1)
  • Phidget cables (i.e. 3002_0, 3003_0, 3004_0 )
     

⚠️ There are various types of Phidget cables available for the connection. Please consult the Phidgets website for the TMP1101 and click on Connection & Compatibility to learn whether the device supports the Phidgets cable you use.

 


Setup options


Direct connection

  • A direct connection applies when adding new probes independently of the roaster's readout. 
  • The newly added probe can be connected directly to the Cropster Connector. 


Dual connection

  • A dual connection applies when the roaster is equipped with a dual probe. 
  • A dual probe is a probe with two sensors inside the hull and two pairs of wires that allow a simultaneous connection to Cropster and the roaster's readout.


Splicing connection

 

⚠️ Hardware splicing is strongly discouraged. We do not recommend hardware connection via splicing due to significant safety and equipment risks. If you proceed against this recommendation, you must power off and unplug your roasting machine before attempting the connection. 

 


If none of the above is applicable, the temperature signal can be spliced from the probe into Cropster with the help of an extension wire:

 
  1. Follow the probe cable from the tip of the probe to its end, where the two wires lead into the roaster's control board or the backside of the temperature display.
  2. Take out the temperature probe wires from where they are connected. Remember their position.
    Take a picture before you disconnect the wires, so you can look up their position.

    EURO standard K-type probes. In this example, wires go into a control board. Instead of a roast control board, you may have a temperature display on your machine. Temperature probe wires (and splicing wires) look different depending on the standard your machine uses.
  3. Take the splicing wire as provided with your Cropster Connector.
  4. Twirl the ends of the probe wires firmly together with the splicing wires by color.

    This example shows EURO standard K-type probes and wires.
  5. Put the twisted wires back into the original position (the existing readout) of the temperature probe wires.


VINT Hub + TMP1101 installation

VINT Hub HUB0000 (now HUB0001_0) on the left, connected to a TMP1101 on the right, using a Phidgets cable to connect the two devices.

 

 

⚠️  Disconnect the USB cable from the VINT Hub and turn off your roast machine during the hardware installation.

 

 

  1. Follow the probe cable from the tip of the probe to its end, where the wires appear.
    • In case of dual probes, take the free end that is not connected to the roaster.
    • In case of splicing, take the free end of the splicing wire.
  2. Connect the probe to a free channel of the 4x Thermocouple Phidget (TMP1101) as shown in the table below.
  3. Repeat the installation steps for each sensor, then use the Phidgets cable to connect the TMP1101 to the VINT Hub.
  4. Connect the VINT Hub to your computer with the provided USB cable and proceed with the software setup.

EURO-standard

US-standard

K-type

  • Green wire to number port (e.g., 0)
  • White wire to the corresponding Ground port

K-type

  • Yellow wire to number port (e.g., 0)
  • Red wire to the corresponding Ground port

J-type

  • Black wire to number port (e.g., 0)
  • White wire to the corresponding Ground port

J-type

  • White wire to number port (e.g., 0)
  • Red wire to the corresponding Ground port


Roasting Intelligence Setup

Installing the Roasting Intelligence software

  1. Download Roasting Intelligence.
  2. Complete the installation process by following the steps provided.
  3. Download the Phidget driver.
  4. Double-click the Cropster icon on your desktop to access Roasting Intelligence. 
  5. Click the green Login with the browser button.
  6. You will be directed to the C-sar browser. 
  7. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.
 

Establishing a connection to the machine

 

The images below are for reference and may vary slightly from your screen.

 

 

Important details to keep in mind:

  • Roasting Intelligence automatically detects the specific VINT Hub port where your TMP1101 is connected. No manual port assignment is required.
  • Before you start configuring your roast machine, ensure that you have added it via the online platform C-sar.
  • Only click Save after you've completed all settings in Roasting Intelligence.
 

 

  1. SelectPreferences > Machine > Configuration.
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select the Phidgets Thermocouple Sensor (TMP1101) from the dropdown. 
  5. Click Select to add the connector. 
  6. ⚠️ This step is exclusive to the wireless VINT HUB (e.g., HUB5000). Do not perform this action if you are using a standard wired hub or any other hardware model, as it may cause configuration conflicts:
    Click on the Gear icon in the Connector setup section to open and configure more settings.
  7. Enter the following details:
    • Hostname/IP address: The hostname or IP address of your Wireless VINT Hub
    • Port: The port of the Phidget Server configured on your Wireless VINT Hub
  8. Click OK.
  9. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  10. To activate the measurements, click the green toggle button.
  11. Enable the desired measurements and choose Phidgets Thermocouple Sensor (TMP1101) as the connector type. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  12. Select the Channel. The Channel refers to the port on the TMP1101. If the probe wires are connected to the "0" ports on the TMP1101, then select "0" under Channel. 
  13. Select the Type of Thermocouple.
  14. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  15. Click Save to finalize the changes.
  16. Restart Roasting Intelligence. If the setup was successful, you will see the temperature values displayed on the right-hand side of the screen following the restart.

     

Learn more about the Roasting Intelligence Preferences. 

 

 

Troubleshooting

If the Roasting Intelligence indicates No source connected and/or you cannot see any measurements, please verify the following: 

  • Is the TMP1101 connected to the VINT Hub? 
  • Is the VINT Hub connected to the computer?
  • Is the Phidgets driver installed?
  • Mac only: Has the Phidgets driver been enabled in the Mac's Security & Privacy settings?

 

💡Good To Know:

If Roasting Intelligence shows negative temperature readings, you will have to swap the wires on the board from “G” to “0” (or 1, 2, 3) and the other way round.

 

If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

 
vint hub + tmp1101 tmp1101

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Phidget 1048 (J/K/E/T type Thermocouples) - Roasting Intelligence Setup
  • VINT Hub + TMP1100 (J/K/E/T Type Thermocouples) - Roasting Intelligence Setup
  • J/K/T/E type thermocouples (splicing connection) - Roasting Intelligence (RI) Setup

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand