This manual covers hardware connection, software installation and settings of Cropster’s Roasting Intelligence for J/K/E/T type (UNGROUNDED) Thermocouples

Written by Nikolett Takacs

Updated at July 30th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Connection options Direct connection Dual connection Splicing connection Cropster Connector installation Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting

 

Legal Note

Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.

By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence (RI) software, the user agrees to release Cropster from any liability and assumes any possible risk related to using this measuring device and/or software. Cropster's terms of service apply.

Cropster cannot advise on the installation of the hardware. To ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation. 

 


Specifications

Requirements

  • Ungrounded digital thermocouples type K, J, T, or E
  • Cropster Connector (Phidget 1048)
  • Splicing wire (ad-hoc)


Connection options

Depending on the type of your roaster and thermocouples, there are three connection options: 

  1. Direct connection
  2. Dual probe connection
  3. Splicing connection


Direct connection

A direct connection applies when adding new probes independently from the roaster's readout. The newly added probe can be connected directly to the Cropster Connector. 

Proceed with the Cropster Connector installation.


Dual connection

A dual connection applies when the roaster is equipped with a dual probe. A dual probe is a probe with two sensors inside the hull and two pairs of wires that allow a simultaneous connection to Cropster and the roaster's readout.

Proceed with the Cropster Connector installation.


Splicing connection

If none of the above is applicable, the temperature signal can be spliced from the probe into Cropster, with the help of an extension wire.

Cropster explicitly does not recommend hardware connection via splicing. Your Cropster support person will gladly recommend different connection options for your machine.

Learn how to establish a splicing connection. 

 


Cropster Connector installation

 

Disconnect the USB cable from the Cropster Connector and turn off your roast machine during the hardware installation.

 

 

  1. Follow the probe cable from the tip of the probe to its end, where the two wires appear.
    In the case of dual probes, take the free end that is not connected to the roast machine.
  2. Connect the two wires to any port of the Cropster Connector (e.g., 0/G, 1/G, 2/G, 3/G) with the provided screwdriver, as shown in the table below.
  3. Connect the Cropster Connector via the provided USB cable and proceed with the Roasting Intelligence (RI) setup.

EURO-standard

US-standard

K-type

  • Green wire to number port (e.g. 0)
  • White wire to corresponding G port

K-type

  • Yellow wire to number port (e.g. 0)
  • Red wire to corresponding G port

J-type

  • Black wire to number port (e.g. 0)
  • White wire to corresponding G port

J -type

  • White wire to number port (e.g. 0)
  • Red wire to corresponding G port


Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.
  3. Download the Phidget driver.
  4. Double-click the Cropster icon on your desktop to access Roasting Intelligence (RI).
  5. Click the green Login with the browser button.
  6. You will be directed to the C-sar browser. 
  7. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar. 

 

Establishing a connection to the machine
 

The images below are for reference and may vary slightly from your screen.

 


Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar. 

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select  Temperature sensor (Ungrounded K/J/E/T-type thermocouples) from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose  Temperature sensor (Ungrounded K/J/E/T-type thermocouples)  as the connector type.
  9. Select the Channel.
    The channel refers to the ports on the Cropster Connector. If the probe wires are connected to port 1/G, select 1 under the channel. 
  10. Select the Type of thermocouple.
  11. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  12. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  13. Click Save to finalize the changes. 

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.


Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the Cropster Connector connected to the computer? 
  • Is the Phidgets driver installed?
  • Mac only: Has the Phidgets driver been enabled on the Mac's Security & Privacy settings?

If Roasting Intelligence shows negative temperature readings, you will have to swap the wires on the board from “G” to “0” (or 1, 2, 3) and the other way round.

 

Congratulations! You have successfully set up the Cropster Roasting Intelligence.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

thermocouple sensors roasting setup

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • PT-100/PT-1000 (RTD type temperature sensors) - Roasting Intelligence (RI) Setup
  • J/K/T/E type thermocouples (splicing connection) - Roasting Intelligence (RI) Setup
  • How to resolve jumbled text issues in Roasting Intelligence (RI)
  • Which probes/temperature sensors does Cropster support

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand