Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Cropster Support
  • Home
  • Connecting your roast machine
  • Plug&Play connectors

Froco A-series and I-series - Roasting Intelligence Setup (Beta)

Written by Marta Brekalo

Updated at May 4th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roast
    Getting Started Inventory Management Sample Management Roast Scheduling Roasting Processes Reporting Troubleshooting
  • Roasting Intelligence
    Getting Started Using Roasting Intelligence Roasting Intelligence AI Features Customization and Preferences Troubleshooting
  • Cafe
    Espresso machine connection Getting Started Cafe Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Production Planning Order Management Inventory Management Product Management Reporting Troubleshooting
  • Origin
    Getting Started Operations Reporting
  • Quality Control
    Cupping Physical Analysis
  • Sharing & Exporting Cropster Data
  • Account & Administration
    General Account Management General User Management Troubleshooting
+ More

Table of Contents

Overview Compatible models Requirements Supported measurements and controls Froco I-series Froco A-series Setup Install Roasting Intelligence Establish a connection to the machine Troubleshooting

Overview

This article shows how to connect your Froco A-series or I-series roaster with the Autonics TX4S controller (manufactured 2023 onwards).

Compatible models

  • A-series: FR1A, FR3A, FR5A, FR15A, FR25A, FR50A
  • I-series: FR1i, FR3i, FR5i, FR15i, FR25i, FR50i

Follow this setup article instead for Froco N-series models.

Note: We are currently testing this integration. If you would like to use it, please sign up for our RMM Beta Program before proceeding with the setup.

Requirements

  • USB cable
  • FTDI driver
    • Note: This driver may already be installed on your computer.

Supported measurements and controls

Froco I-series

  • Measurements: 
    • Bean temperature [°]
    • Drum temperature [°]
  • Controls: 
    • Set temperature (Bean temperature set point) [°]

Froco A-series

  • Measurements: 
    • Bean temperature [°]
    • Drum temperature [°]
    • Inlet temperature [°]
    • Gas [%]
    • Airflow [%]
    • Drum speed [%]
    • Gas pressure [Pa]*
  • Controls: 
    • Set temperature (Bean temperature set point) [°]

*Note: The gas pressure readout is only available on recent machines.

Setup

Install Roasting Intelligence

  1. Download the appropriate custom version of Roasting Intelligence for your system:
    1. Windows: x64 version ending in .exe
    2. macOS: version ending in .dmg
    3. Linux: version ending in .rpm or .deb
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster Roasting Intelligence icon on your desktop.
  4. Click the Login with browser button.

     
  5. You will be directed to the sign-in page in your browser. Enter your email and password, then click the green Log in button. Use the same credentials that you use to access our online platform.

Establish a connection to the machine

Before configuring your roast machine in Roasting Intelligence, add it to your account, then follow the steps below:

  1. In the top-left corner of the screen, click on Preferences > Machine > Configuration.
  2. Click on the Machine drop-down menu (a) at the top of the window and select your roasting machine.
  3. Click the + Add connector button (b) to choose your connector from the drop-down menu.
    Add connector button
     
  4. Select Froco PIDs from the list, then click Select:

     
  5. Click the Gear icon next to the added connector:

     
  6. Click the Serial port drop-down menu and:
    1. Serial port:
      1. tty.usbserial for macOS
      2. COM[number] for Windows
    2. Temperature unit: Select the temperature unit that is configured on the roast machine’s display.
    3. Pressure unit: Select the pressure unit that is configured on the roast machine’s gas pressure display.
  7. Click OK.

     
  8. Navigate to the Measurements tab. All supported measurements and controls will be displayed.
  9. To activate the measurements/controls, click the toggles next to every item in the list. If the toggle is green, the item is enabled:
    Activate measurement toggles
     
  10. For every measurement, click on the accompanying drop-down menu labeled Select source … and select Froco PIDs.


    You can change the order of the measurements by moving the Drag and drop icon Drag and Drop icons.
     
  11. Click Save in the bottom right corner of the Preferences window to save the changes.
    Save preferences

After saving the changes, restart Roasting Intelligence. If the setup was successful, you will see the data from supported measurements in the bottom-right part of the screen.

Troubleshooting

If you do not see the measurements in Roasting Intelligence, try the following:

  • Verify that the roasting machine is connected to the computer via a USB cable.
  • Follow the section Establish a connection to the machine back to step 6 and try to select another serial port.

If this does not help, submit a ticket to Cropster Technical Support, and our representatives will assist you.

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Froco A/I series (via USB) - Roasting Intelligence (RI) Setup (Beta)
  • Siatec - Gourmet and Master line with Ethernet port - Roasting Intelligence Setup
  • Coffed Manual SR3, SR5 and SR5 Delta Models (with USB port) - Roasting Intelligence Setup

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand