In this article, you will learn how to connect a Golden Coffee Roasters (Nazar Kahve) roast machine, with touchscreen, to Cropster's Roasting Intelligence.

This integration is currently in alpha stages at Cropster. If you haven’t been invited to participate in testing this integration, but you are interested, please sign up here.

Alpha means that, at Cropster, we have had minimal experience with Golden Roaster roast machines. Therefore, contact with the machine's manufacturer may be required to clarify, and commence the beta program for Golden Roaster. Once we have achieved a connection with your Golden Roaster, you may come across some flaws under everyday conditions. Hence, it will be necessary that you share feedback with us, and let us know whenever you come across any unexpected behavior.

The setup instructions, below, have yet to be confirmed by the roast machine's manufacturer. Cropster does not explicitly recommend the procedure outlined in this manual. Your Cropster support person will gladly recommend you different connection options for such machines.

Specifications

Requirements

Click here for the driver installation guide.

Supported measurements

  • Bean temperature
  • Exhaust temperature

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download the Roasting Intelligence from https://download.cropster.com/
  2. The Cropster installer leads you through all the installation steps.
  3. Open the RI by double-clicking the Cropster icon on the desktop.
  4. Enter your username and password.
    They are the email address and password you were given to access your Cropster account on c-sar.cropster.com.
  5. Check the Remember credentials box if you want to be able to run the RI offline.
  6. Click the Login button.
      

Establishing a connection to the machine

  1. Go to Account > Preferences > Machine tab.
  2. Select the Roast machine you would like to connect from the drop-down menu (e.g. Golden Roasters GR-5)
  3. Select Generic Modbus over serial port from the drop-down for all measurements.
  4. Click on the gear () icon to open more settings.
  5. Copy the settings as shown in the screenshot below, and select the Serial port, and Temperature unit: 
    • Serial port:
      Windows: Choose the COMx option that refers to the connection to the roaster.

      Mac: Choose the USBx option that refers to the connection to the roaster.

    • Temperature unit: Choose Celsius or Fahrenheit according to the temperature unit displayed from the machine's temperature readouts.

  6. Leave the empty fields as they are, then click OK.
  7. Click Save to confirm the changes. The RI requires a restart to apply the settings.

    If the setup was successful, you will be able to see temperature values on the right-hand side of the RI screen after the restart.

    If you have selected a serial port from the RI, and you receive Sources connected from the bottom-right corner of the roasting application, but you can't see live temperature readouts, you may not have selected the serial port referring to the roast machine's connection.

    Learn how to customize your RI user preferences

    Troubleshooting

    If the RI indicates No source connected and/or you cannot see any measurements, please check the following: 

    • Is the roast machine connected to the computer? 
    • Have you downloaded the driver for the USB serial converter?
    • Is the correct serial port within the RI selected?

    Alternative configuration

    If you are receiving Sources connected, and you have selected the Serial port referring to the connection of the roast machine, but you do not have any temperature measurements, try the following settings:

    1. Go to Account > Preferences > Machine tab.
    2. Verify the Roast machine you would like to connect from the drop-down menu (e.g. Golden Roasters GR-5), is still selected.
    3. Select Generic Modbus over serial port from the drop-down for all measurements.
    4. Click on the gear () icon to open more settings.
    5. One at a time, copy the settings as shown in the screenshot below, and select the Serial port, and Temperature unit:
      • Serial port:
        Windows: Choose the COMx option that refers to the connection to the roaster.

        Mac: Choose the USBx option that refers to the connection to the roaster.

      • Temperature unit: Choose Celsius or Fahrenheit according to the temperature unit displayed from the machine's temperature readouts.

    6. Leave the empty fields as they are, then click OK.
    7. Click Save to confirm the changes. The RI requires a restart to apply the settings.

    Beta Alternative Configuration 

    If you have tried the other configurations and are still not getting any readings, try downloading the Beta for this setup.

    1. Download the Beta Roasting Intelligence from https://download-beta.cropster.com/
    2. Go to Account > Preferences > Machine tab.
    3. Verify the Roast machine you would like to connect from the drop-down menu (e.g. Golden Roasters GR-5), is still selected.
    4. Select Generic Modbus over serial port from the drop-down for all measurements.
    5. Click on the gear () icon to open more settings.
    6. One at a time, copy the settings as shown in the screenshot below, and select the Serial port, and Temperature unit:
    7. Continue to activate interpolation of temperature readings, by activating the checkbox. Then click Save to confirm the changes.

    For more detailed information about the interpolation setting, click the link here.


    For further assistance, please create a support ticket by clicking the Support button in the left lower corner of the app. A Cropster support rep will get in touch with you.


    Congratulations! You have successfully set up the Cropster Roasting Intelligence!