This manual covers the connection of a Golden Coffee Roasters (Nazar Kahve) roast machine with touchscreen to Cropster's Roasting Intelligence.

Written by Nikolett Takacs

Updated at August 14th, 2025

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Getting started
    Origin & Lab Roast
  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roasting Intelligence (RI)
    Roasting Intelligence (RI) Setup Customization and Preferences FAQs Roasting Intelligence (RI) App Artificial Intelligence (AI)
  • Using Cropster
    Post-Harvest Processing (Origin) Day to Day Operations Inventory Management Sample Management Roasting Order and Production Management Quality Control Reporting Sharing & Exporting Cropster Data
  • Cafe
    Getting Started Espresso machine connection Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Account & Administration
    General Account Management Roast Account Management Commerce Account Management General User Management Roast User Management
  • Troubleshooting
    General Roasting Intelligence (RI) Roast machine connections
+ More

Table of Contents

Specifications Requirements Supported measurements Roasting Intelligence (RI) Setup Installing the Roasting Intelligence (RI) software Establishing a connection to the machine Troubleshooting
 

This roast machine is currently in the Alpha stage of development at Cropster.

Alpha means that we have limited experience with this particular roast machine. The setup instructions below have yet to be confirmed by the manufacturer. Therefore, the configuration in this article may not work across the entire model range.

If you have not received an invitation to join the beta program for this integration, but are keen on participating and testing out this new feature, please sign up here.

Once the connection is established, you may encounter some daily use flaws. It will be necessary to share such feedback with us, so please let us know if you encounter any unexpected behaviour.

We will be happy to assist in resolving any issues you may encounter or propose alternative connection options.

 


Specifications

Requirements

  • USB cable
  • Driver for the USB serial converter:
    • Windows
    • macOS 
    • Linux

The driver may already be pre-installed with your operating system.

 


Supported measurements

  • Bean temperature
  • Exhaust temperature


Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.
  3. Double-click the Cropster icon on your desktop to access RI.
  4. Click the green Login with the browser button.
  5. You will be directed to the C-sar browser. 
  6. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar. 
 

Establishing a connection to the machine

The images below are for reference and may vary slightly from your screen.

 

Before you begin configuring your roast machine, ensure that you have added it via the online platform C-sar.

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Generic Modbus over serial port from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose Generic Modbus over serial port as the connector type.
  9. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position
  10. Navigate to the Machine > Configuration tab and click on the Gear icon in the Connector setup section to open and configure more settings.
  11. Copy the settings as shown in the screenshot below, and select the Serial port and Temperature unit:
    • Serial port:
      Windows: COMx 
      Mac: USBx
    • Temperature unit: Choose Celsius or Fahrenheit according to the temperature unit displayed on the machine's temperature readouts
  12. Click OK.
  13. Click Save to finalize the changes. 

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.

 Learn more about the Roasting Intelligence (RI) Preferences. 

 

 

Troubleshooting

If RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the roast machine connected to the computer? 
  • Have you downloaded the driver for the USB serial converter?
  • Is the correct serial port within the RI selected?
     

If you have selected a serial port from the RI, and you receive Sources connected from the bottom-right corner of the roasting application, but you can't see live temperature readouts, you may not have selected the serial port referring to the roast machine's connection.

 

Alternative configuration

If you are receiving Sources connected, and you have selected the Serial port referring to the connection of the roast machine, but you do not have any temperature measurements, try the following settings:

  1. Navigate to Preferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. By clicking on the + Add connector option, you can choose your connector from the available options in the dropdown list.
  4. Select Generic Modbus over serial port from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Switch on the measurements you would like to enable and select Generic Modbus over serial port from the dropdown. 
  9. Navigate to the Machine > Configuration tab and click on theGear icon in the Connector setup section next to the previously added connector to open and configure more settings.
  10. One at a time, copy the settings as shown in the screenshot below, and select the Serial port and Temperature unit
    • Serial port:
      Windows: Choose the COMx option that refers to the connection to the roaster
    • Mac: Choose the USBx option that refers to the connection to the roaster
    • Temperature unit: Choose Celsius or Fahrenheit according to the temperature unit displayed on the machine's temperature readouts.
  11. Leave the empty fields as they are, then click OK.
  12. Click Save to confirm the changes. 


Beta Alternative Configuration 

If you have tried the other configurations and are still not getting any readings, try downloading the Beta for this setup.

To access this integration, please register for Beta testing by completing the provided form here.

 
  1. Download the Roasting Intelligence (RI) Beta.
  2. Navigate toPreferences > Machine > Configuration.
  3. To choose the Roast machine, click on the dropdown menu in the Machine section.
  4. By clicking on the + Add connector option, you can choose your connector from the available options in the dropdown list.
  5. Select Generic Modbus over serial port from the dropdown. 
  6. Click Select to add the connector.
  7. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  8. To activate the measurements, simply click the green toggle button.
  9. Switch on the measurements you would like to enable and select Generic Modbus over serial port from the dropdown. 
  10. Navigate to the Machine > Configuration tab and click on theGear icon in the Connector setup section next to the previously added connector to open and configure more settings.
  11. One at a time, copy the settings as shown in the screenshot below, and select the Serial port and Temperature unit:
  12. Continue to activate interpolation of temperature readings by activating the Allow interpolation of temperature reading checkbox.
  13. Click Save to confirm the changes.

Learn more about the interpolation setting.

 

Congratulations! You have successfully set up the Cropster Roasting Intelligence.

Your opinion matters. If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

touchscreen roasters smart roasting

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • Creating Recipes
  • How to create a roast online (Curve Designer)
  • Printing Roast labels from Roasting Intelligence (RI)

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand