Air-Motion Roasters - Roasting Intelligence (RI) Setup

This manual explains how to connect the Air-Motion Roasters machine via USB to Cropster's Roasting Intelligence.




Customers using the TC4 Protocol should reach out to Air-Motion Roasters for assistance in updating their firmware to the Modbus RTU version.

 

Specifications

Requirements

Supported measurements

  • Bean temperature
  • Exhaust temperature

 

Roasting Intelligence (RI) Setup

Installing the Roasting Intelligence (RI) software

  1. Download RI.
  2. Complete the installation process by following the steps provided.

  3. Double-click the Cropster icon on your desktop to access RI.

  4. Enter your username and password.
    💡 Use the same login information that you use to access the online platform C-sar.

  5. Click the Login button.

Check out the Release notes for every version of RI5 to stay updated on the latest features and improvements.

You can access the Release notes directly in RI by clicking on Help > Release Notes.

Establishing a connection to the machine

  1. If you are setting up RI for the first time, click the Select Machine button in the banner at the top or click gear-png-2 Preferences  > Machine > Configuration bottom left to access the Preferences screen.
    📚 Learn how to use the keyboard shortcuts in RI.

  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
    📚 Learn how to add a new roast machine. 
  3. After selecting the machine all supported measurements will load.
    Change the order of the measurements by using the  Drag and Drop icon and moving it into position.
  4. Switch on the measurements you would like to enable and select Generic Modbus over serial port from the dropdown for the measurements. Repeat this step for all measurements you would like to enable.  

    💡 Make your measurement readouts more compact. Choose the size of your measurement readouts by selecting either the Small or Large view for display.

    Screenshot 2024-10-17 at 16.55.36
  5. Click on the Gear  icon to open the settings.
  6. Select the option that refers to the connection of your roast machine:

    Operation System

    Serial port 
    Windows COMx
    Mac USBx
  7. Copy the settings as shown on the screenshot below:
    Screenshot 2024-10-17 at 16.57.38
  8. Choose the temperature unit that corresponds to your machine setup: either Celsius or Fahrenheit.
  9. Click OK.
  10. Click Save to finalize the changes. 

After saving the changes, RI will automatically restart. If the setup was successful, you will see the temperature values displayed on the right-hand side of the RI screen following the restart.Screenshot 2024-07-23 at 12.45.55

📚 Learn more about the Roasting Intelligence (RI) Preferences

Troubleshooting

If the RI indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the roast machine connected to the computer?
  • Have you downloaded the driver for the USB serial converter?

  • Is the correct serial port within the RI selected?

Driver for the USB serial converter

If you cannot select the correct serial port within the RI's Serial port field, your computer may not have the appropriate driver needed to recognize the serial converter's physical connection.

Please reach out to support.cropster.com, and attach the following information in relevance to the USB serial converter used:

  • Brand, and model

  • Serial number

  • Picture of the serial converter

  • RI log files

A Cropster representative will assess the information, and assist in providing the required driver for the USB serial converter used.


Congratulations! You have successfully set up the Cropster Roasting Intelligence!

Check out the Roasting Intelligence (RI5) - Getting Started manual and enjoy tracking your first roasts! More manuals and videos can be found on help.cropster.com