  • Connecting your roast machine
  • Temperature sensors

Phidget 1048 (J/K/E/T Type Ungrounded Thermocouples) - Roasting Intelligence Setup

Written by Nikolett Takacs

Updated at February 20th, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Connecting your roast machine
    General information Plug&Play connectors Alternative connection options Sample & Multi-barrel roasters Temperature sensors Drivers
  • Roast
    Getting Started Inventory Management Sample Management Roast Scheduling Roasting Processes Reporting Troubleshooting
  • Roasting Intelligence
    Getting Started Using Roasting Intelligence Roasting Intelligence AI Features Customization and Preferences Troubleshooting
  • Cafe
    Espresso machine connection Getting Started Cafe Operations Cafe Telemetry Cafe Inventory Recipe Management Assets Management Troubleshooting
  • Commerce
    Getting Started Product Management Order Management Inventory Management Reporting Troubleshooting
  • Origin
    Getting Started Operations Reporting
  • Quality Control
    Cupping Physical Analysis
  • Sharing & Exporting Cropster Data
  • Account & Administration
    General Account Management General User Management Troubleshooting
+ More

Table of Contents

Specifications Requirements Setup options Direct connection Dual connection Splicing connection Cropster Connector installation Roasting Intelligence Setup Installing the Roasting Intelligence software Establishing a connection to the machine Troubleshooting

 

Legal Note

Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.

By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence (RI) software, the user agrees to release Cropster from any liability and assumes any possible risk related to using this measuring device and/or software. Cropster's terms of service apply.

Cropster cannot advise on the installation of the hardware. To ensure safety when installing any hardware on your machine. We recommend consulting with a technician who can help with the installation. 

 


Specifications

Requirements

 

Learn how to identify the Thermocouple type. 

 

 

  • Ungrounded Digital Thermocouples Type K, J, T, or E
  • Cropster Connector (Phidget 1048)
  • Splicing wire (ad-hoc)

Setup options
 

Direct connection
 

  • A direct connection applies when adding new probes independently from the roaster's readout. 
  • The newly added probe can be connected directly to the Cropster Connector. 
     


Dual connection
 

  • A dual connection applies when the roaster is equipped with a dual probe. 
  • A dual probe is a probe with two sensors inside the hull and two pairs of wires that allow a simultaneous connection to Cropster and the roaster's readout.


Splicing connection

 

⚠️ Hardware splicing is strongly discouraged. We do not recommend hardware connection via splicing due to significant safety and equipment risks. If you proceed against this recommendation, you must power off and unplug your roasting machine before attempting the connection. 

 
 


Cropster Connector installation

 

⚠️  Disconnect the USB cable from the Cropster Connector and turn off your roast machine during the hardware installation.

 

 

  1. Follow the probe cable from the tip of the probe to its end, where the two wires appear.
    In the case of dual probes, take the free end that is not connected to the roast machine.
  2. Connect the two wires to any port of the Cropster Connector (e.g., 0/G, 1/G, 2/G, 3/G) with the provided screwdriver, as shown in the table below.
  3. Connect the Cropster Connector via the provided USB cable.
  4. Proceed with the Roasting Intelligence setup. 

EURO-standard

US-standard

K-type

  • Green wire to number port (e.g., 0)
  • White wire to the corresponding G port.

K-type

  • Yellow wire to number port (e.g.,  0)
  • Red wire to the corresponding G port

J-type

  • Black wire to number port (e.g., 0)
  • White wire to the corresponding G port.

J -type

  • White wire to number port (e.g., 0)
  • Red wire to the corresponding G port


Roasting Intelligence Setup

Installing the Roasting Intelligence software

  1. Download Roasting Intelligence.
  2. Complete the installation process by following the steps provided.
  3. Download the Phidget driver.
  4. Double-click the Cropster icon on your desktop to access Roasting Intelligence. 
  5. Click the green Login with the browser button.
  6. You will be directed to the C-sar browser. 
  7. Enter your Username* and Password* and click the green Sign in with password button. 
    Use the same credentials that you use to access the online platform C-sar.

 

Establishing a connection to the machine
 

The images below are for reference and may vary slightly from your screen.

 

 

Important details to keep in mind:

  • Before you start configuring your roast machine, ensure that you have added it via the online platform C-sar.
  • Only click Save after you've completed all settings in Roasting Intelligence.
 


 

  1. SelectPreferences > Machine > Configuration
  2. To choose the Roast machine, click on the dropdown menu in the Machine section.
  3. Click the + Add connector option to choose your connector from the dropdown list.
  4. Select Temperature sensor (Ungrounded K/J/E/T-Type Thermocouples) from the dropdown. 
  5. Click Select to add the connector.
  6. Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
  7. To activate the measurements, simply click the green toggle button.
  8. Enable the desired measurements and choose the Temperature sensor (Ungrounded K/J/E/T-type Thermocouples) as the connector type. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  9. Select the Channel.
    The channel refers to the ports on the Cropster Connector. If the probe wires are connected to port 1/G, select 1 under the channel. 
  10. Select the Type of thermocouple.
  11. (Optional) Click the toggle button to turn on (or off) the Rate of Rise (RoR) curve for your measurements.
  12. (Optional) Change the order of the measurements by using theDrag and Drop icon and move it into position.
  13. Click Save to finalize the changes. 
  14. Restart Roasting Intelligence. If the setup was successful, you will see the temperature values displayed on the right-hand side of the screen following the restart.

     

Learn more about the Roasting Intelligence Preferences. 

 


Troubleshooting

If Roasting Intelligence indicates No source connected and/or you cannot see any measurements, please check the following: 

  • Is the Cropster Connector connected to the computer? 
  • Is the Phidget driver installed?
  • Mac only: Has the Phidget driver been enabled on the Mac's Security & Privacy settings?

 

If Roasting Intelligence shows negative temperature readings, you will have to swap the wires on the board from “G” to “0” (or 1, 2, 3) and the other way round.

 

 


If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com. 

probat ug roasting intelligence setup j/k/e/t type undgrounded thermocouples phidget 1048

Was this article helpful?

Yes
No
Give feedback about this article

Related Articles

  • What is the difference between ungrounded and grounded Thermocouples
  • Which probes/temperature sensors does Cropster support
  • VINT Hub + TMP1101 (J/K/E/T Type Thermocouples) - Roasting Intelligence Setup
  • What is the optimal length of the Thermocouple wire

Contact

USA: +1 916-550-1682

(MON – FRI 8 AM – 5 PM PST)

Contact Us

  • Download Roast Intelligence
  • Create SLIC QR-Code
  • Scan SLIC QR-Code
  • Connect your Roast Machine
  • Sign up for RMM Beta Program
  • About Us
  • Careers
  • Contact
  • Partners
  • Privacy
  • Legal Notice
  • Terms of Service
  • EU Whistleblowing directive
  • Create a Support Ticket
  • Cropster Helpdesk
  • Cropster System Status
  • Product Updates
Expand