Differential Pressure Sensor (Phidgets 1136/1137/1138) - Roasting Intelligence Setup (Beta)
Table of Contents
This roast machine is currently in the Beta stage of development at Cropster.
To access this integration, please register for Beta testing by completing the provided form here.
Legal Note
Please read this installation and configuration guide carefully, as any mishandling could lead to permanent device damage.
By connecting a Phidget device or temperature probe to any computer or by installing Cropster’s Roasting Intelligence software, the user agrees to release Cropster from any liability and assumes any possible risk related to the use of this measuring device and/or software. Cropster's terms of service apply.
Cropster cannot advise on the installation of the hardware, and to ensure safety when installing any hardware on your machine, Cropster recommends consulting with a technician who can help with the installation.
Specifications
Requirements
-
VINT Hub (HUB0001_0) or PhidgetInterfaceKit 8/8/8
- HUB0001_0 replaced the HUB0000_0
- Differential Air Pressure Sensor (Phidget 1136, Phidget 1137, Phidget 1138)
- Phidget cables (e.g. 3002_0, 3003_0, etc.)
Adding measurements in Roasting Intelligence
The Differential Air Pressure Sensor Phidget setup can be used to track the following measurements in Roasting Intelligence:
- Drum pressure [Pa]
-
Airflow [%]
⚠️ Strict Usage Limitations:
Phidgets has explicitly advised that this hardware is not suitable for reading Gas or Gas pressure. It is engineered strictly for reading Air measurements only.
Utilizing this hardware for gas-related readings is a severe misuse of the equipment and poses an extreme risk of accidents and/or total equipment destruction.
Differential Air Pressure Sensor Phidget Installation
Source: www.phidgets.com
Via VINT Hub HUB0001_0 (or HUB0000_0 depending on your setup)

- Connect the Differential Air Pressure Sensor Phidget to any port of the VINT Hub with the Phidgets cable.
- Connect the VINT Hub to your computer with the USB cable.
Via Phidget InterfaceKit 8/8/8 (Phidget 1018)
- Connect the Differential Air Pressure Sensor Phidget into the InterfaceKit's "Analog Inputs" port (0 through 7) with the Phidget cable.
- Connect the InterfaceKit to your computer with the USB cable.
Roasting Intelligence Setup
Installing the Roasting Intelligence software
- Download the Beta version of Roasting Intelligence.
- Complete the installation process by following the steps provided.
- Download the Phidget driver.
- Double-click the Cropster icon on your desktop to access Roasting Intelligence.
-
Click the green Login with the browser button.

- You will be directed to the C-sar browser.
-
Enter your Username* and Password* and click the green Sign in with password button.
Use the same credentials that you use to access the online platform C-sar.
Establishing a connection to the device
The images below are for reference and may vary slightly from your screen.
Important details to keep in mind:
- Before you start configuring your roast machine, ensure that you have added it via the online platform C-sar.
- Only click Save after you've completed all settings in Roasting Intelligence.
- Select
Preferences > Machine > Configuration - To choose the Roast machine, click on the dropdown menu in the Machine section.
- Click the + Add connector option to choose your connector from the dropdown list.
- Select Phidgets Differential Air Pressure Sensor from the dropdown.
-
Click Select to add the connector.

- Click on the
Gear icon in the Connector setup section to open and configure more settings. -
From the Phidget hub dropdown menu, select whether you use a...
- VINT Hub
- InterfaceKit
-
⚠️ This step is exclusive to the wireless VINT HUB (e.g., HUB5000):
Enter the following details:- Hostname/IP address: This can be identified after connecting the Wireless VINT HUB to a network.
- Port: 5661
-
⚠️ This is only relevant if you previously selected Phidgets Differential Air Pressure Sensor [%] during the “Add Connector” process (Step 4).
The following information will be pre-selected:- Pressure at 0% [Pa]: 0.0
- Pressure at 100% [Pa]: 2000.0
-
Click OK.
- Navigate to the Machine > Measurements tab. All supported measurements will be displayed.
- To activate the measurements, simply click the green toggle button.
- Enable the desired measurements and choose Phidgets Differential Air Pressure Sensor as the connector type.
-
Select the Type of your Differential Air Pressure Sensor:
- Phidget 1136
- Phidget 1137
- Phidget 1138
-
Under Hub port, select the port where your Differential Air Pressure Sensor Phidget is connected to the Hub port:
- VINT Hub: The Hub port refers to the port on the VINT Hub. For example. If the Phidget is connected to Hub port 0, select 0.
- InterfaceKit: The Hub port refers to the InterfaceKit's Analog Inputs (e.g, ports). For example, if the Phidget is connected to Analog Input 7, select 7.
- (Optional) Change the order of the measurements by using the
Drag and Drop icon and move it into position. -
Click Save to finalize the changes.

-
Restart Roasting Intelligence. If the setup was successful, you will see the temperature values displayed on the right-hand side of the screen following the restart.
⚠️ This screenshot is for illustrative purposes only to show where measurements appear on the Roasting Intelligence screen. For specific setup instructions, please refer to the "Adding Measurements to Roasting Intelligence" section in this article.
Learn more about the Roasting Intelligence Preferences.
Troubleshooting
If you cannot see the measurement, please verify the following:
- Is the Phidget 1136/1137/1138 connected to the VINT Hub/InterfaceKit?
- Is the VINT Hub/InterfaceKit connected to the computer?
- Have you selected the correct Hub port?
- Is the Phidgets22 Driver installed?
- Mac only: Has the Phidgets Driver been enabled on the Mac's Security & Privacy settings?
If you have further questions, feedback, or concerns, please submit a support ticket directly from support.cropster.com.